
Device studies for RHTP plans
Every device study,in one chart.
- In pilot
- Real patient data only after a signed BAA
- Codes from rules with sources, never a model
Device studies in ZunovaMD, in numbers
- 7Study devices on file, each with its FDA record
- 4Device makers
- 3Study kinds: retinal, ankle-brachial index, sudomotor
- 1Chart for every study, on the order it answers
One study,from order to claim.
A study that lives only in a vendor's portal is one more login for staff and one more place a result can wait. ZunovaMD puts each study on the order it answers, where the chart and the claim already are.
- Order
A clinician signs the order
In the patient's visit. The order joins the worklist of each matching device at that site.
In ZunovaMD
- Capture
The device takes the study
The device's portal reads the worklist, or staff pick the order as they upload, so the study carries its order from the start.
At the device
- Send
The study lands on the order
Images, a report and the device's findings, as PDF, JPEG, PNG or DICOM files.
The maker's connection, or staff upload today
- Read
Someone reads and signs it
A staff member, a physician or a paired autonomous AI records what the study shows.
In ZunovaMD
- Code
The read sets the code
The CPT code goes on the claim from a rule with its source.
In ZunovaMD
What the clinic sees,in ZunovaMD.
Our own screens, on synthetic patients. Open orders sit on each device's worklist, studies wait for a read, and a study that came in without an order waits for staff to confirm its match.


For RHTP teams,a count of every study.
The report counts studies by month, site and kind: received, read, referable, held for billing review and the codes the reads chose. It carries no patient names and exports to CSV for a grant report.
| Month | Site | Study | Received | Read | Referable | Billing review | Codes |
|---|---|---|---|---|---|---|---|
| 2026-10 | Clinic A | Retinal screen | 38 | 36 | 5 | 0 | 92228 × 30, 92227 × 6 |
| 2026-10 | Clinic A | Ankle-brachial index and PVR | 14 | 14 | 3 | 0 | 93922 × 11, 93923 × 3 |
| 2026-10 | Clinic B | Sudomotor test | 6 | 6 | 1 | 6 | 95999 × 6 |
Each state decides what its Rural Health Transformation Program plan funds. The law lists training and technical help for rural hospitals to adopt technology such as remote monitoring and artificial intelligence [2]. CMS's FAQ of October 31, 2025 adds three points [1]:
- Buying new patient monitoring devices is one example of an allowable use.
- The funds cannot replace payment for clinical services that insurance could cover.
- Added modules and interfaces for an existing EMR are allowable uses outside the 5% EMR replacement limit.
We make no claim that a device or ZunovaMD qualifies. That is each state's decision.
What is the Rural Health Transformation Program?Devices on file,each with its FDA record.
A clinic can add any study device. Until we have read its FDA record, it shows “FDA record not on file”, and billing picks the code for its reads.

Product photo: Phelcom Technologies Phelcom Technologies
Phelcom Eyer and Eyer 2
Retinal screen
510(k) cleared: K221329, K251353
Phelcom Eyer and Eyer 2 in ZunovaMD
Product photo: Optomed Optomed
Optomed Aurora
Retinal screen
510(k) cleared: K180378
Optomed Aurora in ZunovaMDTopcon
Topcon NW400
Retinal screen
510(k) cleared: K141481
Topcon NW400 in ZunovaMD
Product photo: LD Technology LD Technology
LD Technology TM Flow
Ankle-brachial index and PVR, Sudomotor test
510(k) cleared: K143152, K173696, K152216, K160956
LD Technology TM Flow in ZunovaMD
Device and product names are trademarks of their owners. Naming a device does not mean its maker endorses ZunovaMD, and ZunovaMD holds no FDA clearance of its own.
Works with,device by device.
Each device here has an FDA record on file. A vendor connection is a separate step, and the last column shows where each one stands.
| Works with | FDA record | Study type | Today | Vendor connection |
|---|---|---|---|---|
| Phelcom TechnologiesEyer Retinal Camera NM-STD | 510(k) cleared: K221329 | Retinal screen | Staff upload the vendor's report or images: works today | Not connected yet |
| Phelcom TechnologiesEyer 2 | 510(k) cleared: K251353 | Retinal screen | Staff upload the vendor's report or images: works today | Not connected yet |
| TopconTopcon NW400 | 510(k) cleared: K141481 | Retinal screen | Staff upload the vendor's report or images: works today | Not connected yet |
| OptomedOptomed Aurora | 510(k) cleared: K180378 | Retinal screen | Staff upload the vendor's report or images: works today | Not connected yet |
| LD TechnologyTM Flow System | 510(k) cleared: K143152, K173696, K152216, K160956 | Ankle-brachial index and PVR, Sudomotor test | Staff upload the vendor's report or images: works today | Not connected yet |
| LD TechnologyTM-ABI system | 510(k) cleared: K143152 | Ankle-brachial index and PVR | Staff upload the vendor's report or images: works today | Not connected yet |
| LD TechnologySudoC | 510(k) cleared: K152216 | Sudomotor test | Staff upload the vendor's report or images: works today | Not connected yet |
Make a study device that is not listed?Tell us about your device
Which code a read bills,and where the rule comes from.
ZunovaMD sets the code from these rules, each with its source and the day we read it. A rule picks a code. It does not promise payment: each payer decides what it pays.
| Study | Who reads | Code | What happens | Source |
|---|---|---|---|---|
| Retinal screen | Clinical staff review | CPT 92227 | Remote imaging for detection of retinal disease, reviewed by clinical staff. | CY 2021 Physician Fee Schedule final rule, 85 FR 84629, remote retinal imaging, read 2026-11-18AAPC, CPT 2021 retinal imaging codes, read 2026-11-18 |
| Retinal screen | Physician read | CPT 92228 | Remote imaging with physician or QHP review, interpretation and report. | CY 2021 Physician Fee Schedule final rule, 85 FR 84629, remote retinal imaging, read 2026-11-18AAO, telehealth retinal codes, read 2026-11-18 |
| Retinal screen | Autonomous AI read | CPT 92229 | Point-of-care automated analysis and report, only when the AI's clearance names the camera. | CY 2021 Physician Fee Schedule final rule, 85 FR 84629, remote retinal imaging, read 2026-11-18AAPC, how CPT categorizes AI procedures, read 2026-11-18 |
| Ankle-brachial index and PVR | Physician read, one or two levels | CPT 93922 | Limited bilateral noninvasive physiologic study, one or two levels. | CMS ASC prior authorization operational guide (2026), 93922 descriptor, read 2026-11-18LCD L35761, Non-Invasive Peripheral Arterial Vascular Studies (WPS), read 2026-11-18 |
| Ankle-brachial index and PVR | Physician read, three or more levels | CPT 93923 | Complete bilateral study, three or more levels. | CY 2011 Physician Fee Schedule final rule, Table 54, read 2026-11-18Medicare NCCI Policy Manual 2026, chapter XI, read 2026-11-18 |
| Ankle-brachial index and PVR | Clinical staff review | No code | Waits for billing review. 93922 and 93923 include the interpretation. A physician reads the study before it bills. | LCD L35761, Non-Invasive Peripheral Arterial Vascular Studies (WPS), read 2026-11-18Billing and coding article A57593 (WPS), read 2026-11-18 |
| Sudomotor test | Any read | CPT 95999 | Waits for billing review. Sudoscan-type sudomotor devices do not meet the 95923 description under the Novitas article; billing confirms the contractor's rule. | CMS billing and coding article A54954 (Novitas, LCD L35395), read 2026-11-18 |
What exists today,and what waits.
ZunovaMD is in pilot. Real patient data needs a live clinic site, and a vendor's connection also needs a signed business associate agreement (BAA) with that vendor.
- In pilotThe device API: a worklist of signed orders and study upload, with a key for each device
- In pilotStaff upload of PDF, JPEG, PNG and DICOM files on the patient's order
- In pilotReads by staff, a physician or a paired AI, with the code set on the claim
- In pilotThe report by month, site and kind, with a CSV export
- Per vendorA signed BAA with each device vendor before its connection carries real patient data
- In pilotImages shown in the study page, DICOM included. Formats the page cannot show download
- In pilotA suggested patient match for a study that arrives without an order, which staff confirm
Make a study device?Send studies to the order.
Send studies from your retinal camera or ABI system into a clinic's ZunovaMD chart: a worklist of signed orders, one call per study, a key per device.
Apply as a device makerThe device studies API for vendorsDevice study questions,answered plainly.
For RHTP teams, clinic owners and medical directors: what ZunovaMD does with a device study, and what it does not.
Talk with our teamA one-time test on a clinic device that produces images or a report, such as a retinal screen or an ankle-brachial index. It answers a signed order, someone reads it, and the read decides the billing code. A reading from a home blood pressure cuff is not a study.
No. ZunovaMD files each study as the device sent it and never analyzes an image or a waveform. A staff member or a physician reads the study in ZunovaMD, or the clinic accepts an autonomous AI's read when that AI's FDA record names the camera.
No. ZunovaMD holds no FDA clearance of its own. The FDA records on these pages belong to the devices and AI readers, each shown as the FDA lists it, with its number and source.
Each state decides what its plan funds. CMS's FAQ of October 31, 2025 gives buying new patient monitoring devices as one example of an allowable use, and says the funds cannot replace payment for clinical services insurance could cover. We make no claim that a device or ZunovaMD qualifies.
The device's worklist carries the signed order, and the study comes back with it. A study that arrives without an order waits in a list until a staff member matches it to a signed order at that site. ZunovaMD never matches a patient by name on its own.
A live clinic site in ZunovaMD, and for a vendor's connection, a signed business associate agreement (BAA) with that vendor, recorded in ZunovaMD. Until then the device API takes only synthetic studies on a test site.
Sources
See a study gofrom device to claim.
Thirty minutes on your devices: an order on the worklist, a study on the order, a read, the code on the claim and the month's report. Synthetic data only.