Device studies
Ankle-brachial index,read by a physician.
Illustrative image, AI-generated
Two codes,set by the levels measured.
Both codes include the interpretation. In ZunovaMD a staff review files the study but sends no code until a physician reads it.
| Study | Who reads | Code | What happens | Source |
|---|---|---|---|---|
| Ankle-brachial index and PVR | Physician read, one or two levels | CPT 93922 | Limited bilateral noninvasive physiologic study, one or two levels. | CMS ASC prior authorization operational guide (2026), 93922 descriptor, read 2026-11-18LCD L35761, Non-Invasive Peripheral Arterial Vascular Studies (WPS), read 2026-11-18 |
| Ankle-brachial index and PVR | Physician read, three or more levels | CPT 93923 | Complete bilateral study, three or more levels. | CY 2011 Physician Fee Schedule final rule, Table 54, read 2026-11-18Medicare NCCI Policy Manual 2026, chapter XI, read 2026-11-18 |
| Ankle-brachial index and PVR | Clinical staff review | No code | Waits for billing review. 93922 and 93923 include the interpretation. A physician reads the study before it bills. | LCD L35761, Non-Invasive Peripheral Arterial Vascular Studies (WPS), read 2026-11-18Billing and coding article A57593 (WPS), read 2026-11-18 |
What the physician records,in four answers.
- Levels
How many were measured
The physician picks one or two levels, or three or more. That answer sets 93922 or 93923.
- Impression
What the study shows
Normal, Abnormal, not referable, Referable: refer the patient, Ungradable: repeat the study: the same words as every other study.
- Note
The physician's note
A short note files with the read, next to the device's report and files.
- Code
The claim line
ZunovaMD puts the code on the claim. A staff review alone sends none, so the study waits for a physician.
93922 describes ABIs plus a waveform or volume recording at one or two levels [2]. Under WPS's Medicare rules, an ABI alone is part of the physical exam and is not covered, and a hand-held Doppler reading without a hard copy is part of the exam too [3] [4]. Rules differ by Medicare contractor, so billing checks yours. ZunovaMD keeps the device's report and waveforms on the order as they were sent.
ABI systems on file,with their FDA records.
Any ABI system's report can be added by staff. These are the systems whose FDA records we have read.

Product photo: LD Technology LD Technology
LD Technology TM Flow
Ankle-brachial index and PVR, Sudomotor test
510(k) cleared: K143152, K173696, K152216, K160956
LD Technology TM Flow in ZunovaMD
Device and product names are trademarks of their owners. Naming a device does not mean its maker endorses ZunovaMD, and ZunovaMD holds no FDA clearance of its own.
How device studies work in ZunovaMDABI questions,answered plainly.
Codes, levels and who reads, as ZunovaMD applies them.
Talk with our teamNo. 93922 and 93923 include the interpretation, so in ZunovaMD a staff review alone sends no code. The study waits until a physician reads it.
The physician records how many levels the study measured. One or two levels sets 93922, three or more sets 93923. The code comes from that answer and a rule with a source, never from a model.
Not under WPS's Medicare rules. 93922 describes ABIs plus a waveform or volume recording at one or two levels, and WPS treats an ABI alone as part of the physical exam, not covered. Rules differ by Medicare contractor, so billing checks yours.
No. ZunovaMD keeps the device's report and files as sent and never analyzes a waveform. The physician reads them and records the result.
Any ABI system's report can be added by staff upload. LD Technology's TM Flow and its TM-ABI part are on file with their FDA records, and any vendor can send studies through the ZunovaMD device API.
Sources
- National Heart, Lung, and Blood Institute: Peripheral Artery Disease, Diagnosis, read 2026-11-18
- CMS ASC prior authorization operational guide (2026), 93922 descriptor, read 2026-11-18
- LCD L35761, Non-Invasive Peripheral Arterial Vascular Studies (WPS), read 2026-11-18
- Billing and coding article A57593 (WPS), read 2026-11-18
See an ABI studygo from device to claim.
Thirty minutes: an order on the device's worklist, the report on the order, a physician's read with its levels, and the code on the claim. Synthetic data only.